Products
CONTROL POWER TRANSFORMERS
MGM’s Control Power Transformers are specially designed to accommodate the momentary current inrush caused when electromagnetic components are energized.
These transformers deliver excellent secondary voltage requirements and meet or exceed the standards established by UL and cUL. Their rugged construction and quality electrical characteristics ensure reliable operation of electromagnetic devices and trouble-free performance.
Standard features for Control Power transformers include:
- Ratings from 50VA to 750VA
- 50/60 Hz frequency
- Encapsulated Transformer coil
- Insulation system: 130°C rise
- UL listed & CSA certified
- Four standard voltage groups:
- 240/230/220 x 480/460/440 – 120/115/110
- 120 x 240 – 24
- 208/277 – 120
- 240 x 480 – 24
Numquam Eius Modi
Non proident, sunt in culpa qui officia deserunt mollit
Duis aute irure dolor >
Copper | Primary: 240/230/220 x 480/460/440 | Secondary: 120/115/110 | Voltage Config: A
CAT # | RATING | H (in) | W (in) | D (in) | Mounting Depth | Mounting Width | Mounting Hole Depth | Mounting Hole Width | WEIGHT (lbs) |
---|---|---|---|---|---|---|---|---|---|
M22585
| 50
| 2.79
| 3.00
| 3.23
| 2.00
| 2.50
| 0.203
| 0.406
| 2.6
|
M22426
| 75
| 2.79
| 3.00
| 3.73
| 2.50
| 2.50
| 0.203
| 0.406
| 3.5
|
M22427
| 100
| 3.10
| 3.38
| 4.23
| 2.38
| 2.81
| 0.203
| 0.406
| 4.2
|
M22428
| 150
| 3.41
| 3.75
| 4.18
| 2.88
| 3.13
| 0.203
| 0.406
| 6.7
|
M22645
| 200
| 4.04
| 4.50
| 3.96
| 2.50
| 3.75
| 0.203
| 0.406
| 8.5
|
M22429
| 250
| 4.04
| 4.50
| 4.46
| 2.88
| 3.75
| 0.203
| 0.406
| 10.0
|
M22646
| 300
| 4.04
| 4.50
| 4.46
| 3.25
| 3.75
| 0.203
| 0.406
| 11.3
|
M22430
| 350
| 4.04
| 4.50
| 5.19
| 3.75
| 3.75
| 0.203
| 0.406
| 13.6
|
M22431
| 500
| 4.66
| 5.25
| 5.17
| 4.25
| 4.38
| 0.313
| 1.063
| 19.2
|
M22432
| 750
| 4.66
| 5.25
| 6.42
| 5.38
| 4.38
| 0.313
| 1.063
| 28.1
|
Copper | Primary:120 x 240 | Secondary: 24 | Voltage Config: B
CAT # | RATING | H (in) | W (in) | D (in) | Mounting Depth | Mounting Width | Mounting Hole Depth | Mounting Hole Width | WEIGHT (lbs) |
---|---|---|---|---|---|---|---|---|---|
M23485
| 50
| 2.79
| 3.00
| 3.23
| 2.00
| 2.50
| 0.203
| 0.406
| 2.6
|
M23486
| 75
| 2.79
| 3.00
| 3.73
| 2.50
| 2.50
| 0.203
| 0.406
| 3.5
|
M23487
| 100
| 3.10
| 3.38
| 4.23
| 2.38
| 2.81
| 0.203
| 0.406
| 4.2
|
M23488
| 150
| 3.41
| 3.75
| 4.18
| 2.88
| 3.13
| 0.203
| 0.406
| 6.7
|
M23489
| 200
| 4.04
| 4.50
| 3.96
| 2.50
| 3.75
| 0.203
| 0.406
| 8.5
|
M23490
| 250
| 4.04
| 4.50
| 4.46
| 2.88
| 3.75
| 0.203
| 0.406
| 10.0
|
M24817
| 300
| 4.04
| 4.50
| 4.46
| 3.25
| 3.75
| 0.203
| 0.406
| 11.3
|
M23490
| 350
| 4.04
| 4.50
| 5.19
| 3.75
| 3.75
| 0.203
| 0.406
| 13.6
|
M23491
| 500
| 4.66
| 5.25
| 5.17
| 4.25
| 4.38
| 0.313
| 1.063
| 19.2
|
Copper | Primary: 208/277 | Secondary:120 | Voltage Config: C
CAT # | RATING | H (in) | W (in) | D (in) | Mounting Depth | Mounting Width | Mounting Hole Depth | Mounting Hole Width | WEIGHT (lbs) |
---|---|---|---|---|---|---|---|---|---|
M24454
| 50
| 2.79
| 3.00
| 3.23
| 2.00
| 2.50
| 0.203
| 0.406
| 2.6
|
M24455
| 75
| 2.79
| 3.00
| 3.73
| 2.50
| 2.50
| 0.203
| 0.406
| 3.5
|
M24456
| 100
| 3.10
| 3.38
| 4.23
| 2.38
| 2.81
| 0.203
| 0.406
| 4.2
|
M24457
| 150
| 3.41
| 3.75
| 4.18
| 2.88
| 3.13
| 0.203
| 0.406
| 6.7
|
M24820
| 200
| 4.04
| 4.50
| 3.96
| 2.50
| 3.75
| 0.203
| 0.406
| 8.5
|
M24458
| 250
| 4.04
| 4.50
| 4.46
| 2.88
| 3.75
| 0.203
| 0.406
| 10.0
|
M24821
| 300
| 4.04
| 4.50
| 4.46
| 3.25
| 3.75
| 0.203
| 0.406
| 11.3
|
M24459
| 350
| 4.04
| 4.50
| 5.19
| 3.75
| 3.75
| 0.203
| 0.406
| 13.6
|
M24460
| 500
| 4.66
| 5.25
| 5.17
| 4.25
| 4.38
| 0.313
| 1.063
| 19.2
|
M24461
| 750
| 4.66
| 5.25
| 6.42
| 5.38
| 4.38
| 0.313
| 1.063
| 28.1
|
Copper | Primary: 240 x 480 | Secondary: 24 | Voltage Config: D
CAT # | RATING | H (in) | W (in) | D (in) | Mounting Depth | Mounting Width | Mounting Hole Depth | Mounting Hole Width | WEIGHT (lbs) |
---|---|---|---|---|---|---|---|---|---|
M23493
| 50
| 2.79
| 3.00
| 3.23
| 2.00
| 2.50
| 0.203
| 0.406
| 2.6
|
M23494
| 75
| 2.79
| 3.00
| 3.73
| 2.50
| 2.50
| 0.203
| 0.406
| 3.5
|
M23495
| 100
| 3.10
| 3.38
| 4.23
| 2.38
| 2.81
| 0.203
| 0.406
| 4.2
|
M23496
| 150
| 3.41
| 3.75
| 4.18
| 2.88
| 3.13
| 0.203
| 0.406
| 6.7
|
M24818
| 200
| 4.04
| 4.50
| 3.96
| 2.50
| 3.75
| 0.203
| 0.406
| 8.5
|
M23497
| 250
| 4.04
| 4.50
| 4.46
| 2.88
| 3.75
| 0.203
| 0.406
| 10.0
|
M24819
| 300
| 4.04
| 4.50
| 4.46
| 3.25
| 3.75
| 0.203
| 0.406
| 11.3
|
M23498
| 350
| 4.04
| 4.50
| 5.19
| 3.75
| 3.75
| 0.203
| 0.406
| 13.6
|
M23499
| 500
| 4.66
| 5.25
| 5.17
| 4.25
| 4.38
| 0.313
| 1.063
| 19.2
|
FEATURES
STANDARD FEATURES
- Ratings from 50VA to 750VA
- Four standard voltage groups:
- 240/230/220 x 480/460/440 – 120/115/110
- 120 x 240 – 24
- 208/277 – 120
- 240 x 480 – 24
- 50/60 Hz frequency
- Completely enclosed transformer coils
- Insulation system: 130°C rise
- UL listed & CSA certified
TESTING AND QUALITY
UL Listed, CSA Certified, with a UL 3R Enclsoure. Meets or exceeds all listing criteria including NEMA, ANSI and OSHA standards
Benefits
PROVIDES HIGH DEGREE OF SECONDARY VOLTAGE STABILITY
MGM’s Control Power Transformers are specially designed to accommodate the momentary current inrush caused when electromagnetic components are energized. Upon start up, most electromagnetic devices require anywhere from 3-10 times their normal operating current for 30-50 milliseconds. Control power transformers provide the high degree of secondary voltage stability required for that period.